Indoor end of use equipment
Selince Fan coil
Features
Ultra-quiet operation
Sound pressure down to 20dB
Friendly appliance
19cm of height to ensure easier installation and less space taken
Fan motor
Rubber brushless DC fan motor with aero dynamic blades
Hygiene
Condensate drain pan with ABS anti-bacterial layer and best structural design
Thermostat
Maintain a constant temperature for comfort, adjustable wind speed and dehumidification function
Model |
KMFC-036RP-DA |
KMFC-045RP-DA |
KMFC-056RP-DA |
KMFC-063RP-DA |
||
KMFC-036LP-DA |
KMFC-045LP-DA |
KMFC-056LP-DA |
KMFC-063LP-DA |
|||
Air Flow |
CMH |
HH |
510 |
680 |
850 |
1020 |
H |
470 |
605 |
760 |
915 |
||
M |
420 |
525 |
660 |
800 |
||
L |
370 |
435 |
560 |
660 |
||
LL |
310 |
360 |
460 |
540 |
||
Rated Heating Capacity |
kW |
600C |
5.40 |
6.60 |
8.70 |
10.00 |
450C |
3.40 |
4.10 |
5.40 |
6.20 |
||
Rated Cooling Capacity |
kW |
70C |
3.30 |
4.00 |
5.20 |
6.20 |
EER |
W/W |
/ |
133 |
100 |
112 |
90 |
COP |
W/W |
600C |
338 |
338 |
483 |
526 |
W/W |
450C |
213 |
241 |
300 |
326 |
|
Motor Power Input |
W (H) |
12PA |
16 |
17 |
18 |
19 |
Noise |
dB (A) |
12Pa |
30/27/24/22/20 |
34/31/28/24/21 |
38/32/28/24/22 |
37/35/31/27/23 |
Water Flow |
m3/h |
0.57 |
0.69 |
0.89 |
1.07 |
|
Water Pressure Drop |
kPa |
17 |
22 |
29 |
36 |
|
Dimension |
(H×W×D) mm |
190*910*445 |
190*1180*445 |
|||
Air Inlet Dimension |
(H×W) mm |
760*171 |
1030*171 |
|||
Air Outlet Dimension |
(H×W) mm |
750*130 |
1020*130 |
|||
Static Pressure |
Pa |
0~30 |
||||
Coil |
Type |
Hydrophilic Finned Heat Exchanger |
||||
Motor |
Type |
Brushless Hermatic EC Motor |
||||
Power Supply (V/Ph/Hz) |
220/1/50 |
|||||
Fan |
Type |
Rubber Centrifugal Fan |
||||
Quantity |
2 |
2 |
3 |
3 |
||
Condensed Water Pan |
Type |
ABS Foaming |
||||
Drain Pipe Connection |
mm |
VP25 (OD Ø32) |
||||
Water Connection |
mm |
G3/4” |
||||
Net Weight |
kg |
19 |
19 |
23.5 |
23.5 |
Note:
1. Cooling capacity, heating capacity, water flow and pressure drop are parameters tested under ultra-high speed.
2. Cooling mode DB/WB: 27/19.5℃ , DHW inlet/outlet temp.: 7/12℃ . Heating mode DB: 21℃ , WB ≤ 15℃ , hot water inlet temp.: 60℃ /45℃ , water flow same as cooling mode.
3. Rated air flow is tested under standard air quality and DB=20℃ .
4. Sound pressure is tested for rear air return installation (without filter) in a semi-anechoic room.
5. The model, parameters and performance will be changed due to the improvement of the product. The specific parameters are subject to the actual product and the nameplate.