air source heat pump

ArW monoblock I

EasyLife Series DC Inverter EVI Heat Pump from 3E is a multifunctional device designed for heating, cooling and supplying rooms with hot water.

The solution combines the use of environmentally friendly R32 refrigerant with high energy efficiency efficient EVI technology solution. 

The device has an A+++ energy label ERP ensures stable operation at outdoor temperatures to -30℃.

The 3E Monoblock Heat Pump has been equipped with a color LCD control panel, function, wifi and the ability to precisely control the temperature in the range of ± 0.1 ℃ providing users the highest quality of „smart home” solutions.

Energy label A+++ tested by TUV

  • Energy label A+++ 
  • SCOP up to 4.72 
  • Intelligent defrosting 
  • Two electric heater control ports 
  • Multiple noise reduction processes 
  • CE 
  • Keymark 
  • Only Heating 
  • Only Cooling 
  • Only DHW

Monoblock heat pump application scenario

Model

3E030

-DKZLRS-A

3E040

-DKZLRS-A

3E050

-DKZLRS-A

3E060

-DKZLRS-A

3E080

-DKZLRS-A

3E100

-DKZLRS-A

Heating Condition: Ambient Temp. (DB/WB): 7°C/6°C, Water temperature(inlet/outlet): 30°C/35°C

Heating capacity range (kW)

1.57~8.40

4.40~13.00

5.9~18.2

7.5~23.0

10.2~28.0

12.8~35.0

Heating input range (kW)

0.32~1.87

0.90~3.02

1.20~4.11

1.53~5.23

2.07~6.36

2.61~7.99

Current range (A)

1.42~8.30

1.39~4.68/

4.12~13.8

1.86~6.37/

5.49~18.8

2.37~8.11

3.70~11.4

4.67~14.3

Cop range

4.49~4.91

4.30~4.90

4.43~4.92

4.40~4.90

4.40~4.92

4.38~4.90

Cooling Condition: Ambient Temp. (DB/WB): 12°C/7°C, Water temperature(inlet/outlet): 35°C/24°C

Cooling capacity range (kW)

0.99~6.22

2.80~8.20

3.81~11.53

4.73~14.6

6.54~19.8

8.13~24.6

Cooling input power(kW)

0.29~2.18

0.85~3.31

1.11~4.05

1.39~5.14

1.92~6.97

2.42~8.75

Current range (A)

1.28~9.67

1.32~5.13/

3.89~15.1

1.72~6.28/

5.08~18.5

2.16~7.97

3.43~12.5

4.33~15.6

Eer range

2.85~3.41

2.48~3.29

2.85~3.43

2.84~3.40

2.84~3.40

2.81~3.36

DHW Condition: Ambient Temp. (DB/WB): 7°C/6°C, Water temperature(inlet/outlet): 15°C/55°C

Heating capacity range (kw)

1.28~6.81

3.52~10.50

4.80~14.72

6.1~18.5

12.3~20.4

13.6~22.6

Heating input range (kw)

0.31~2.13

0.88~3.39

1.17~4.60

1.53~5.97

2.8~5.37

3.09~5.95

Current range (A)

1.38~9.45

1.36~5.26/

4.03~15.5

1.82~7.15/

5.35~21.1

2.37~9.26

5.0~9.6

5.52~10.6

Cop range

3.2~4.1

3.1~4.0

3.2~4.1

3.1~4.0

3.8~4.4

3.8~4.4

Erp level (35°C)

A+++

A+++

A+++

A+++

A+++

A+++

Erp level (55°C)

A++

A++

A++

A++

A++

A++

Refrigerant

R32

Power supply

230V/1Ph/

50-60Hz

380V-400V/3Ph/50-60Hz or

220V-230V/1Ph/50-60Hz

380V-400V/3Ph/

50-60Hz

Working area (°C)

-30~43

Water circulation (m³/h)

1.4

2.2

3.1

4.0

4.8

6

Water pressure drop (kPa)

31

25

35

45

40

50

Ip grade (level of protection)

IPX4

IPX4

IPX4

IPX4

IPX4

IPX4

Anti-electric shock rate

I

I

I

I

I

I

Noise (dB(A))

≤53

≤55

≤57

≤58

≤62

≤66

Net weight/Gross weight (kg)

110/120

140/150

170/180

180/190

210/220

230/240

Diameter of pipe (mm)

DN25

DN25

DN25

DN25

DN32

DN32

Body size(W*D*H) (mm)

970×475×835

1100×475×985

1050×480×1330

1050×480×1330

1160×500×1580

1160×500×1580

Loading quantity (20GP/40GP/40HQ)

44/88/88

44/88/88

22/42/42

22/42/42

18/40/40

18/40/40

Operating water temperature (°C) DHW

9~60

Operating water temperature (°C) Heating

9~60

Operating water temperature (°C) Cooling

7~35